vicorpower.com Applications Engineering: 800 927.9474 Page 9
Field Replacement Unit Instructions.
> Remove input power connector.
(this should never be attempted with the input power cable inserted)
> Remove output power connections
> Remove four screws, from the back panel (ref 1) two either side (ref; 2)
> Remove back panel (ref 1)
> Pull back the insulating material to gain access to the fan connector (ref 7)
> Depress the latching point on the fan connector (ref 7)
> The connector is polarized and removes vertically from the PCB housing
> Remove four screws (ref 4). The fan guard and fan are now free from the back panel.
> Insert new fan, making sure the arrow (ref 3) is pointed in the direction shown.
(Towards the inside of the MicroPAC)
> Replace fan guard in the correct orientation (ref 5)
> Replace 4 screws (ref 4). The torque on these screw should be 5-6 inch-lb. (Friction tight)
> Insert fan connector (ref 7) into the fan housing.
When inserted correctly you will not be able to remove without depressing the latch
> Fold the insulating material back
> Replace the back panel (ref 1) making sure the fan wire is routed to the side of the fan.
> Replace the four screws (ref 2). The torque on these screw is 5-6 inch-lb
> Never apply power to the MicroPAC until all of the reassembly is complete.
Estimated replacement time 15 minutes
Figure 5:
Fan Assembly