1.1.5 Power Shed Mode Functional Description
On power up with the power shed function enabled all four output channels are initially
enabled, channel one to four LED’s should be illuminated. Circuitry internal to the MicroPAC
monitors the amount of current drawn from the MicroPAC and is proportional to the
customer load.
If the load falls into category 1, the following will be observed.
Aer 5 seconds output 4 will turn o, aer 10 seconds output 3 will turn o,
aer 15 seconds output 2 will turn o.
If the customer load falls into category 2, the following will be observed.
Aer 5 seconds output 4 will turn o, aer 10 seconds output 3 will turn o,
output 1 and 2 will remain on.
If the customer load falls into category 3, the following will be observed.
Aer 5 seconds output 4 will turn o, output 1, 2 and 3 will remain on.
If the customer load falls into category 4, all output will remain on.