VICOR MicroPAC Specifications Page 18

  • Download
  • Add to my manuals
  • Print
  • Page
    / 21
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 17
vicorpower.com Applications Engineering: 800 927.9474 Page 15
MicroPAC Model Numbering Scheme
Model Number: UPa - bbbb - cde
Where
a = number of outputs from 1 to 4
b = equals a character denoting output 1 voltage and power
b = equals a character denoting output 2 voltage and power
b = equals a character denoting output 3 voltage and power
b = equals a character denoting output 4 voltage and power
One character will denote a null for an output
c, d, e will be characters denoting box level options such as fan cooling, conduction cooling, convection
cooling, interfacing scheme, and rohs status.
Examples:
UP1-FZZZ-FSG Denotes a single output of 24 V 1200 W
with a standard fan, standard TTL signaling and control, RoHS compliant
UP4-AAAA-LIN Denotes 4 output unit, each output is 12 V 300 W.
The fan is a -40°C capable unit, the control bus is digital, and the unit is non-RoHS
Character Vout Watts
A 12 300
B 12 600
C 12 900
D 12 1200
E 24 600
F 24 1200
Character Vout Watts
G 48 325
H 48 650
I 48 975
J 48 1300
K 36 900
Z Null Null
Output Voltage and Voltage Table (bbbb)
U P a - b b b b c d e
Number of
outputs,
1 to 4
Output Configuration
Fill in character from chart below for each output
b = Vout Watts b = Vout Watts
A 12 300 G 48 325
B 12 600 H 48 650
C 12 900 I 48 975
D 12 1200 J 48 1300
E 24 600 K 36 900
F 24 1200 M [a] [a]
Z [b] [b]
[a] M defines a slot with an air block filler, no BCM board
[b] Z indicates the slot is populated with a BCM board that is
connected in series or parallel with the adjacent slot
Cooling
F = Fan
L = -40°C Fan
Interface Customer Option
Non-Safety Related
S = Standard (TTL levels)
Signaling and Control
I = Digital Bus Signaling
and Control
RoHS Compliant
G = RoHS
N = Non-RoHS
Page view 17
1 2 ... 13 14 15 16 17 18 19 20 21