Vicor VI Chip BCM Customer Evaluation Board User Manual

Browse online or download User Manual for Hardware Vicor VI Chip BCM Customer Evaluation Board. Vicor VI Chip BCM Customer Evaluation Board User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 5
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
UG:001 vicorpower.com Applications Engineering: 800 927.9474 Page 1
Introduction
n Oscilloscope probe jack for output voltage and ripple measurements
n Simple to use
n Ring lug or solder connections
n Parallelable
Introduction
The Customer Evaluation Board oers a convenient means to evaluate the performance
of Vicor’s BCM bus converter and has been optimized for user convenience. Refer to the
appropriate BCM data sheet for performance and operating limits. The data sheets are
available for downloading at vicorpower.com.
It is important to remember the fast response of most BCMs can readily show the
limitations of the source, load, and associated wiring connected to the evaluation board.
Care should be exercised to minimize stray source and load impedances in order to fully
exercise the BCM.
Please refer to Figure 1 for locations of the input and output connections as viewed from
the component side. Wires may be soldered directly to the pads instead of ring lugs if
desired to minimize circuit impedances.
VI Chip
®
BCM
®
Customer Evaluation Board
User Guide
USER GUIDE | UG:001
Contents Page
Features 1
Introduction 1
Set Up 3
Recommended 5
Hardware
Thermals 5
Ordering Info 5
Page view 0
1 2 3 4 5

Summary of Contents

Page 1 - User Guide

UG:001 vicorpower.com Applications Engineering: 800 927.9474 Page 1Introductionn Oscilloscope probe jack for output voltage and ripple measurem

Page 2

UG:001 vicorpower.com Applications Engineering: 800 927.9474 Page 2TMRSVPC+IN–INCL2.5264,0Ø 0.20 Ty p5.081.6541.9+OUT– OUTC1BCMJ1TP1TP2TP7TP4TP6

Page 3

UG:001 vicorpower.com Applications Engineering: 800 927.9474 Page 3Set UpThe Customer Evaluation Board should be set up as follows:Note: Care sh

Page 4 - BCM Customer Evaluation

UG:001 vicorpower.com Applications Engineering: 800 927.9474 Page 4Input Current MeasurementA current probe can be passed around the +in lead co

Page 5 - The Power Behind Performance

The Power Behind PerformanceRev 1.1 08/2014 vicorpower.com Applications Engineering: 800 927.9474 Page 5Recommended Hardware:Quantity Descripti